Helper command for local PIO Unit Testing.
platformio test [OPTIONS]
pio test [OPTIONS]
Run locally tests from PlatformIO based project. More details about PlatformIO PIO Unit Testing.
This command allows you to apply the tests for the environments specified in “platformio.ini” (Project Configuration File).
Process specified environments. More details platformio run --environment
Process only the tests where the name matches specified patterns. More than one pattern is allowed. If you need to filter some tests for a specific environment, please take a look at test_filter option from “platformio.ini” (Project Configuration File).
Pattern |
Meaning |
---|---|
|
matches everything |
|
matches any single character |
|
matches any character in seq |
|
matches any character not in seq |
For example, platformio test --filter "mytest*" -i "test[13]"
Ignore tests where the name matches specified patterns. More than one pattern is allowed. If you need to ignore some tests for a specific environment, please take a look at test_ignore option from “platformio.ini” (Project Configuration File).
Pattern |
Meaning |
---|---|
|
matches everything |
|
matches any single character |
|
matches any character in seq |
|
matches any character not in seq |
For example, platformio test --ignore "mytest*" -i "test[13]"
A port that is intended for firmware uploading. To list available ports please use platformio device list command.
If upload port is not specified, PlatformIO will try to detect it automatically.
A Serial/UART port that PlatformIO uses as communication interface between PlatformIO Unit Test Engine and target device. To list available ports please use platformio device list command.
If test port is not specified, PlatformIO will try to detect it automatically.
Specify the path to project directory. By default, --project-dir
is equal
to current working directory (CWD
).
Skip building stage.
Skip uploading stage
Disable software reset via Serial.DTR/RST
before test running. In this case,
need to press “reset” button manually after firmware uploading.
Warning
If board does not support software reset via Serial.DTR/RTS
you
should add >2 seconds delay before UNITY_BEGIN()`.
We need that time to establish a ``Serial
communication between host
machine and target device. See PIO Unit Testing.
Set initial RTS
line state for Serial Monitor (0
or 1
),
default 1
. We use it to gather test results via Serial connection.
Set initial DTR
line state for Serial Monitor (0
or 1
),
default 1
. We use it to gather test results via Serial connection.
Shows detailed information when processing environments.
This option can be set globally using force_verbose setting
or by environment variable PLATFORMIO_SETTING_FORCE_VERBOSE
.
For the examples please follow to PIO Unit Testing page.