ipmiutil_smcoem - OEM commands for SuperMicro servers
ipmiutil smcoem [-mx -NPRUEFJTVY] commands
ipmiutil smcoem is a function that uses SuperMicro OEM IPMI
commands to perform platform-specific functions.
- -m 002000
- Show FRU for a specific MC (e.g. bus 00, sa 20, lun 00). This could be
used for PICMG or ATCA blade systems. The trailing character, if present,
indicates SMI addressing if 's', or IPMB addressing if 'i' or not
present.
- -x
- Causes extra debug messages to be displayed.
- -N nodename
- Nodename or IP address of the remote target system. If a nodename is
specified, IPMI LAN interface is used. Otherwise the local system
management interface is used.
- -P/-R rmt_pswd
- Remote password for the nodename given. The default is a null
password.
- -U rmt_user
- Remote username for the nodename given. The default is a null
username.
- -E
- Use the remote password from Environment variable IPMI_PASSWORD.
- -F drv_t
- Force the driver type to one of the followng: imb, va, open, gnu, landesk,
lan, lan2, lan2i, kcs, smb. Note that lan2i means lan2 with intelplus. The
default is to detect any available driver type and use it.
- -J
- Use the specified LanPlus cipher suite (0 thru 17): 0=none/none/none,
1=sha1/none/none, 2=sha1/sha1/none, 3=sha1/sha1/cbc128,
4=sha1/sha1/xrc4_128, 5=sha1/sha1/xrc4_40, 6=md5/none/none, ...
14=md5/md5/xrc4_40. Default is 3.
- -T
- Use a specified IPMI LAN Authentication Type: 0=None, 1=MD2, 2=MD5,
4=Straight Password, 5=OEM.
- -V
- Use a specified IPMI LAN privilege level. 1=Callback level, 2=User level,
3=Operator level, 4=Administrator level (default), 5=OEM level.
- -Y
- Yes, do prompt the user for the IPMI LAN remote password. Alternatives for
the password are -E or -P.
- intrusion
This command resets any chassis intrusion condition that may have
occurred.
- bmcstatus
[enable|disable]
This command gets or sets the BMC service status. Alone,
without arguments, it gets the BMC status as either enabled or disabled. With
an argument of either enable or disable, it will also set the BMC status as
specified.
- firmware
This command gets the extra firmware version information, if
available.
- lanport
[dedicated|lan1|failover]
This command gets or sets the IPMI LAN interface port. If
set to dedicated, only the dedicated IPMI NIC can be configured for IPMI LAN.
If set to lan1, only the first onboard NIC (LAN1) can be configured for IPMI
LAN. If set to failover, both the dedicated and onboard LAN1 port would be
configured for IPMI LAN, with the same IP address.
See http://ipmiutil.sourceforge.net/ for the latest version of
ipmiutil and any bug fix list.
Copyright (C) 2013 Andy Cress
See the file COPYING in the distribution for more details
regarding redistribution.
This utility is distributed in the hope that it will be useful,
but WITHOUT ANY WARRANTY.
Andy Cress <arcress at users.sourceforge.net>