fi_cntr(3) | @VERSION@ | fi_cntr(3) |
fi_cntr - Completion and event counter operations
fi_cntr_open / fi_close : Allocate/free a counter
fi_cntr_read : Read the current value of a counter
fi_cntr_readerr : Reads the number of operations which have completed in error.
fi_cntr_add : Increment a counter by a specified value
fi_cntr_set : Set a counter to a specified value
fi_cntr_wait : Wait for a counter to be greater or equal to a threshold value
#include <rdma/fi_domain.h> int fi_cntr_open(struct fid_domain *domain, struct fi_cntr_attr *attr, struct fid_cntr **cntr, void *context); int fi_close(struct fid *cntr); uint64_t fi_cntr_read(struct fid_cntr *cntr); uint64_t fi_cntr_readerr(struct fid_cntr *cntr); int fi_cntr_add(struct fid_cntr *cntr, uint64_t value); int fi_cntr_adderr(struct fid_cntr *cntr, uint64_t value); int fi_cntr_set(struct fid_cntr *cntr, uint64_t value); int fi_cntr_seterr(struct fid_cntr *cntr, uint64_t value); int fi_cntr_wait(struct fid_cntr *cntr, uint64_t threshold, int timeout);
domain : Fabric domain
cntr : Fabric counter
attr : Counter attributes
context : User specified context associated with the counter
value : Value to increment or set counter
threshold : Value to compare counter against
timeout : Time in milliseconds to wait. A negative value indicates infinite timeout.
Counters record the number of requested operations that have completed. Counters can provide a light-weight completion mechanism by suppressing the generation of a full completion event. They are useful for applications that only need to know the number of requests that have completed, and not details about each request. For example, counters may be useful for implementing credit based flow control or tracking the number of remote processes which have responded to a request.
Counters typically only count successful completions. However, if an operation completes in error, it may increment an associated error value. That is, a counter actually stores two distinct values, with error completions updating an error specific value.
fi_cntr_open allocates a new fabric counter. The properties and behavior of the counter are defined by struct fi_cntr_attr.
struct fi_cntr_attr { enum fi_cntr_events events; /* type of events to count */ enum fi_wait_obj wait_obj; /* requested wait object */ struct fid_wait *wait_set; /* optional wait set */ uint64_t flags; /* operation flags */ };
events : A counter captures different types of events. The specific type which is to counted are one of the following:
wait_obj : Counters may be associated with a specific wait object. Wait objects allow applications to block until the wait object is signaled, indicating that a counter has reached a specific threshold. Users may use fi_control to retrieve the underlying wait object associated with a counter, in order to use it in other system calls. The following values may be used to specify the type of wait object associated with a counter: FI_WAIT_NONE, FI_WAIT_UNSPEC, FI_WAIT_SET, FI_WAIT_FD, and FI_WAIT_MUTEX_COND. The default is FI_WAIT_NONE.
wait_set : If wait_obj is FI_WAIT_SET, this field references a wait object to which the event counter should attach. When an event is added to the event counter, the corresponding wait set will be signaled if all necessary conditions are met. The use of a wait_set enables an optimized method of waiting for events across multiple event counters. This field is ignored if wait_obj is not FI_WAIT_SET.
flags : Flags are reserved for future use, and must be set to 0.
The fi_close call releases all resources associated with a counter. When closing the counter, there must be no opened endpoints, transmit contexts, receive contexts or memory regions associated with the counter. If resources are still associated with the counter when attempting to close, the call will return -FI_EBUSY.
The fi_cntr_control call is used to access provider or implementation specific details of the counter. Access to the counter should be serialized across all calls when fi_cntr_control is invoked, as it may redirect the implementation of counter operations. The following control commands are usable with a counter:
FI_GETOPSFLAG (uint64_t *) : Returns the current default operational flags associated with the counter.
FI_SETOPSFLAG (uint64_t *) : Modifies the current default operational flags associated with the counter.
FI_GETWAIT (void **) : This command allows the user to retrieve the low-level wait object associated with the counter. The format of the wait-object is specified during counter creation, through the counter attributes. See fi_eq.3 for addition details using control with FI_GETWAIT.
The fi_cntr_read call returns the current value of the counter.
The read error call returns the number of operations that completed in error and were unable to update the counter.
This adds the user-specified value to the counter.
This adds the user-specified value to the error value of the counter.
This sets the counter to the specified value.
This sets the error value of the counter to the specified value.
This call may be used to wait until the counter reaches the specified threshold, or until an error or timeout occurs. Upon successful return from this call, the counter will be greater than or equal to the input threshold value.
If an operation associated with the counter encounters an error, it will increment the error value associated with the counter. Any change in a counter's error value will unblock any thread inside fi_cntr_wait.
If the call returns due to timeout, -FI_ETIMEDOUT will be returned. The error value associated with the counter remains unchanged.
It is invalid for applications to call this function if the counter has been configured with a wait object of FI_WAIT_NONE or FI_WAIT_SET.
Returns 0 on success. On error, a negative value corresponding to fabric errno is returned.
fi_cntr_read / fi_cntr_readerr : Returns the current value of the counter.
Fabric errno values are defined in rdma/fi_errno.h.
In order to support a variety of counter implementations, updates made to counter values (e.g. fi_cntr_set or fi_cntr_add) may not be immediately visible to counter read operations (i.e. fi_cntr_read or fi_cntr_readerr). A small, but undefined, delay may occur between the counter changing and the reported value being updated. However, a final updated value will eventually be reflected in the read counter value, with the order of the updates maintained.
fi_getinfo(3), fi_endpoint(3), fi_domain(3), fi_eq(3), fi_poll(3)
OpenFabrics.
2017-09-14 | Libfabric Programmer's Manual |