sane-u12(5) | SANE Scanner Access Now Easy | sane-u12(5) |
sane-u12 - SANE backend for Plustek USB flatbed scanners, based on older parport designs
The sane-u12 library implements a SANE (Scanner Access Now Easy) backend that provides access to USB flatbed scanners based on Plusteks' ASIC 98003 (parallel-port ASIC) and a GeneSys Logics' USB-parport bridge chip.
The backend is able to support some early Plustek USB scanner based their old parport design around the ASIC 98003 and other rebadged Plustek devices. The following tables will give you a short overview.
If your Plustek scanner has another Product ID, then the device is NOT supported by this backend.
Vendor Plustek - ID: 0x07B3
---------------------------------------------------------- Model: Vendor-ID: Product-ID: ---------------------------------------------------------- OpticPro U12 0x07B3 0x0001 OpticPro U1212 0x07B3 0x0001 OpticPro UT12 0x07B3 0x0001
Vendor KYE/Genius
-------------------------------------------------------- USB Model: Vendor-ID: Product-ID: -------------------------------------------------------- ColorPage Vivid III USB 0x07B3 0x0001 ColorPage HR6 V1 0x0458 0x2004
To use your scanner with this backend, you need at least two entries in the configuration file @CONFIGDIR@/u12.conf
[usb] tells the backend, that the following devicename (here /dev/usbscanner) has to be interpreted as USB scanner device. If vendor- and product-id has not been specified, the backend tries to detect this by its own. If device is set to auto then the next matching device is used.
The Options:
option warmup t
option lampOff t
option lOffonEnd b
See the u12.conf file for examples.
Note:
You have to make sure, that the USB subsystem is loaded correctly and you have
access to the device-node. For more details see sane-usb (5) manpage.
You might use sane-find-scanner to check that you have access to your
device.
Note:
If there's no configuration file, the backend defaults to device
auto
Example: export SANE_DEBUG_U12=10
sane(7), sane-usb(5), sane-plustek(5),
@DOCDIR@/u12/U12.changes
http://www.gjaeger.de/scanner/u12/
Please send any information and bug-reports to:
SANE Mailing List
Additional info and hints can be obtained from our
Mailing-List archive at:
http://www.sane-project.org/mailing-lists.html
or directly from the projects' homepage at:
http://www.gjaeger.de/scanner/u12/
To obtain debug messages from the backend, please set the
environment-variable SANE_DEBUG_U12 before calling your favorite
scan-frontend (i.e. xscanimage).
i.e.: export SANE_DEBUG_U12=20 ; xscanimage
The value controls the verbosity of the backend.
* The driver is in alpha state, so please don't expect too much!!!
* When using libusb, it might be, that the backend hangs. In that case, reconnect the scanner.
14 Jul 2008 | @PACKAGEVERSION@ |