richcomm_usb - Driver UPS equipment using Richcomm dry-contact to USB solution
This man page only documents the specific features of the richcomm_usb driver. For information about the core driver, see nutupsdrv(8).
The Richcomm dry-contact to USB solution is a generic interface that is used to upgrade an existing (RS-232) contact closure UPS interface to USB. As such, all the limitations of the underlying contact closure interface apply. This means that you will only get the essentials in ups.status: OL, OB, and LB. See also genericups(8).
Most contact-closure UPSes will not power down the load if the line power is present. This can create a race when using slave upsmon(8) systems. See the upsmon(8) man page for more information.
The solution to both of these problems is to upgrade to a smart protocol UPS of some kind that allows detection and proper load cycling on command.