DS1977(3) | One-Wire File System | DS1977(3) |
DS1977 - Password Protected 32kbit Memory iButton
Non-volatile memory.
37 [.]XXXXXXXXXXXX[XX][/[ memory | pages/page.[0-510|ALL] | set_number/full | set_number/read | set_password/enabled | set_password/full | set_password/read | use_number/full | use_number/read | use_password/full | use_password/read | address | crc8 | id | locator | r_address | r_id | r_locator | type ]]
37 DS1977
read-write, binary
32704 bytes of memory. Possibly protected by a password.
read-write, binary
Memory is split into 511 pages of 64 bytes each. ALL is an aggregate of
the pages. Each page is accessed sequentially.
write-only, ascii
Passwords entered as numbers, either decimal, or hex of form
0x0123456789ABCDEF. Handled the same as set_password/xxx
read-write, yes-no
Turn on/off password protection for the DS1977, or return the current
state.
write-only, binary
Passwords (8 byte values) that allow read or full access to the DS1977 memory.
The password set by set_password/xxx are stored in the DS1977 and
locally in the program as well (as if use_password/xxx was also
called).
write-only, binary
Passwords (8 byte values) that allow read or full access to the DS1977 memory.
The password set by
write-only, ascii
Passwords entered as numbers, either decimal, or hex of form
0x0123456789ABCDEF. Handled the same as use_password/xxx
write-only, binary
Passwords (8 byte values) that allow read or full access to the DS1977 memory.
The password set by use_password/xxx are stored in the program and
must match the passwords stored in the DS1977. Changing the DS1977 passwords
using set_password/xxx will change these values as well.
use_password/xxx are stored in the program and must match the
passwords stored in the DS1977. Changing the DS1977 passwords using
set_password/xxx will change these values as well.
read-only, ascii
The entire 64-bit unique ID. Given as upper case hexadecimal digits (0-9A-F).
address starts with the family code
r address is the address in reverse order, which is often used
in other applications and labeling.
read-only, ascii
The 8-bit error correction portion. Uses cyclic redundancy check. Computed
from the preceding 56 bits of the unique ID number. Given as upper case
hexadecimal digits (0-9A-F).
read-only, ascii
The 8-bit family code. Unique to each type of device. Given as upper
case hexadecimal digits (0-9A-F).
read-only, ascii
The 48-bit middle portion of the unique ID number. Does not include the family
code or CRC. Given as upper case hexadecimal digits (0-9A-F).
r id is the id in reverse order, which is often used in other
applications and labeling.
read-only, ascii
Uses an extension of the 1-wire design from iButtonLink company that
associated 1-wire physical connections with a unique 1-wire code. If the
connection is behind a Link Locator the locator will show a unique
8-byte number (16 character hexadecimal) starting with family code FE.
If no Link Locator is between the device and the master, the
locator field will be all FF.
r locator is the locator in reverse order.
read-only, yes-no
Is the device currently present on the 1-wire bus?
read-only, ascii
Part name assigned by Dallas Semi. E.g. DS2401 Alternative packaging
(iButton vs chip) will not be distiguished.
None.
1-wire is a wiring protocol and series of devices designed and manufactured by Dallas Semiconductor, Inc. The bus is a low-power low-speed low-connector scheme where the data line can also provide power.
Each device is uniquely and unalterably numbered during manufacture. There are a wide variety of devices, including memory, sensors (humidity, temperature, voltage, contact, current), switches, timers and data loggers. More complex devices (like thermocouple sensors) can be built with these basic devices. There are also 1-wire devices that have encryption included.
The 1-wire scheme uses a single bus master and multiple slaves on the same wire. The bus master initiates all communication. The slaves can be individually discovered and addressed using their unique ID.
Bus masters come in a variety of configurations including serial, parallel, i2c, network or USB adapters.
OWFS is a suite of programs that designed to make the 1-wire bus and its devices easily accessible. The underlying principle is to create a virtual filesystem, with the unique ID being the directory, and the individual properties of the device are represented as simple files that can be read and written.
Details of the individual slave or master design are hidden behind a consistent interface. The goal is to provide an easy set of tools for a software designer to create monitoring or control applications. There are some performance enhancements in the implementation, including data caching, parallel access to bus masters, and aggregation of device communication. Still the fundamental goal has been ease of use, flexibility and correctness rather than speed.
The DS1977 (3) is an iButton with static memory that is optionally protected by a password.
All 1-wire devices are factory assigned a unique 64-bit address. This address is of the form:
Addressing under OWFS is in hexadecimal, of form:
where 01 is an example 8-bit family code, and 12345678ABC is an example 48 bit address.
The dot is optional, and the CRC code can included. If included, it must be correct.
http://pdfserv.maxim-ic.com/en/ds/DS1977.pdf
owfs (1) owhttpd (1) owftpd (1) owserver (1) owdir (1) owread (1) owwrite (1) owpresent (1) owtap (1)
owfs (5) owtap (1) owmon (1)
owtcl (3) owperl (3) owcapi (3)
DS1427 (3) DS1904 (3) DS1994 (3) DS2404 (3) DS2404S (3) DS2415 (3) DS2417 (3)
DS2401 (3) DS2411 (3) DS1990A (3)
DS1982 (3) DS1985 (3) DS1986 (3) DS1991 (3) DS1992 (3) DS1993 (3) DS1995 (3) DS1996 (3) DS2430A (3) DS2431 (3) DS2433 (3) DS2502 (3) DS2506 (3) DS28E04 (3) DS28EC20 (3)
DS2405 (3) DS2406 (3) DS2408 (3) DS2409 (3) DS2413 (3) DS28EA00 (3)
DS1822 (3) DS1825 (3) DS1820 (3) DS18B20 (3) DS18S20 (3) DS1920 (3) DS1921 (3) DS1821 (3) DS28EA00 (3) DS28E04 (3) EDS0064 (3) EDS0065 (3) EDS0066 (3) EDS0067 (3) EDS0068 (3) EDS0071 (3) EDS0072 (3) MAX31826 (3)
DS1922 (3) DS2438 (3) EDS0065 (3) EDS0068 (3)
DS2450 (3)
DS2890 (3)
DS2436 (3) DS2437 (3) DS2438 (3) DS2751 (3) DS2755 (3) DS2756 (3) DS2760 (3) DS2770 (3) DS2780 (3) DS2781 (3) DS2788 (3) DS2784 (3)
DS2423 (3)
LCD (3) DS2408 (3)
DS1977 (3)
DS2406 (3) TAI8570 (3) EDS0066 (3) EDS0068 (3)
EEEF (3) DS2438 (3)
http://www.owfs.org
Paul Alfille (paul.alfille@gmail.com)
2003 | OWFS Manpage |