DOKK / manpages / debian 11 / fence-agents / fence_intelmodular.8.en
FENCE_AGENT(8) System Manager's Manual FENCE_AGENT(8)

fence_intelmodular - Fence agent for Intel Modular

fence_intelmodular is an I/O Fencing agent which can be used with Intel Modular device (tested on Intel MFSYS25, should work with MFSYS35 as well).

Note: Since firmware update version 2.7, SNMP v2 write support is removed, and replaced by SNMP v3 support. So agent now has default SNMP version 3. If you are using older firmware, please supply -d for command line and snmp_version option for your cluster.conf.

fence_intelmodular accepts options on the command line as well as from stdin. Fenced sends parameters through stdin when it execs the agent. fence_intelmodular can be run by itself with command line options. This is useful for testing and for turning outlets on or off from scripts.

Vendor URL: http://www.intel.com

Fencing action (Default Value: reboot)
Set the community string
IP address or hostname of fencing device This parameter is always required.
TCP/UDP port to use for connection with device (Default Value: 161)
Login password or passphrase
Script to run to retrieve password
Physical plug number on device, UUID or identification of machine This parameter is always required.
Set authentication protocol (MD5|SHA)
Set privacy protocol password
Script to run to retrieve privacy password
Set privacy protocol (DES|AES)
Set security level (noAuthNoPriv|authNoPriv|authPriv)
Specifies SNMP version to use (1|2c|3)
Login name
Disable logging to stderr. Does not affect --verbose or --debug-file or logging to syslog.
Verbose mode. Multiple -v flags can be stacked on the command line (e.g., -vvv) to increase verbosity.
Level of debugging detail in output. Defaults to the number of --verbose flags specified on the command line, or to 1 if verbose=1 in a stonith device configuration (i.e., on stdin).
Write debug information to given file
Display version information and exit
Display help and exit
Separator for CSV created by 'list' operation (Default Value: ,)
Wait X seconds before fencing is started (Default Value: 0)
Disable timeout (true/false) (default: true when run from Pacemaker 2.0+)
Wait X seconds for cmd prompt after login (Default Value: 5)
Test X seconds for status change after ON/OFF (Default Value: 20)
Wait X seconds after issuing ON/OFF (Default Value: 0)
Wait X seconds for cmd prompt after issuing command (Default Value: 3)
Count of attempts to retry power on (Default Value: 1)
Path to snmpget binary (Default Value: /usr/bin/snmpget)
Path to snmpset binary (Default Value: /usr/bin/snmpset)
Path to snmpwalk binary (Default Value: /usr/bin/snmpwalk)

Power on machine.
Power off machine.
Reboot machine.
This returns the status of the plug/virtual machine.
List available plugs with aliases/virtual machines if there is support for more then one device. Returns N/A otherwise.
List available plugs with aliases/virtual machines and their power state if it can be obtained without additional commands.
Check the health of fence device
Display the XML metadata describing this resource.

The operational behavior of this is not known.
Validate if all required parameters are entered.

Fencing action (Default Value: reboot)
Set the community string
IP address or hostname of fencing device This parameter is always required. Obsoletes: ipaddr
TCP/UDP port to use for connection with device (Default Value: 161)
Login password or passphrase Obsoletes: passwd
Script to run to retrieve password Obsoletes: passwd_script
Physical plug number on device, UUID or identification of machine This parameter is always required. Obsoletes: port
Set authentication protocol (MD5|SHA)
Set privacy protocol password
Script to run to retrieve privacy password
Set privacy protocol (DES|AES)
Set security level (noAuthNoPriv|authNoPriv|authPriv)
Specifies SNMP version to use (1|2c|3)
Login name Obsoletes: login
Disable logging to stderr. Does not affect --verbose or --debug-file or logging to syslog.
Verbose mode. Multiple -v flags can be stacked on the command line (e.g., -vvv) to increase verbosity.
Level of debugging detail in output. Defaults to the number of --verbose flags specified on the command line, or to 1 if verbose=1 in a stonith device configuration (i.e., on stdin).
Write debug information to given file Obsoletes: debug
Display version information and exit
Display help and exit
Separator for CSV created by 'list' operation (Default Value: ,)
Wait X seconds before fencing is started (Default Value: 0)
Disable timeout (true/false) (default: true when run from Pacemaker 2.0+)
Wait X seconds for cmd prompt after login (Default Value: 5)
Test X seconds for status change after ON/OFF (Default Value: 20)
Wait X seconds after issuing ON/OFF (Default Value: 0)
Wait X seconds for cmd prompt after issuing command (Default Value: 3)
Count of attempts to retry power on (Default Value: 1)
Path to snmpget binary (Default Value: /usr/bin/snmpget)
Path to snmpset binary (Default Value: /usr/bin/snmpset)
Path to snmpwalk binary (Default Value: /usr/bin/snmpwalk)
2009-10-20 fence_intelmodular (Fence Agent)