SoCounter(3IV)() | SoCounter(3IV)() |
SoCounter — triggered integer counter
SoBase > SoFieldContainer > SoEngine > SoCounter
#include <Inventor/engines/SoCounter.h>
Inputs from class SoCounter:
SoSFShort min
SoSFShort max
SoSFShort step
SoSFTrigger trigger
SoSFShort reset
Outputs from class SoCounter:
(SoSFShort) output
(SoSFTrigger) syncOut
Methods from class SoCounter:
SoCounter()
Methods from class SoEngine:
static SoType getClassTypeId()
virtual int getOutputs(SoEngineOutputList &list)
const
SoEngineOutput * getOutput(const SbName
&outputName) const
SbBool getOutputName(const SoEngineOutput *output,
SbName &outputName) const
SoEngine * copy() const
static SoEngine * getByName(const SbName
&name)
static int getByName(const SbName &name,
SoEngineList &list)
Methods from class SoFieldContainer:
void setToDefaults()
SbBool hasDefaultValues() const
SbBool fieldsAreEqual(const SoFieldContainer *fc)
const
void copyFieldValues(const SoFieldContainer *fc,
SbBool copyConnections = FALSE)
SbBool set(const char *fieldDataString)
void get(SbString &fieldDataString)
virtual int getFields(SoFieldList &resultList)
const
virtual SoField * getField(const SbName
&fieldName) const
SbBool getFieldName(const SoField *field, SbName
&fieldName) const
SbBool isNotifyEnabled() const
SbBool enableNotify(SbBool flag)
Methods from class SoBase:
void ref()
void unref() const
void unrefNoDelete() const
void touch()
virtual SoType getTypeId() const
SbBool isOfType(SoType type) const
virtual void setName(const SbName &name)
virtual SbName getName() const
This engine is a counter that outputs numbers, starting at a minimum value, increasing by a step value, and ending with a number that does not exceed the maximum value. It outputs the next number whenever the trigger input is touched. When the maximum number is reached, it starts counting from the beginning again.
At any time the counter can be reset to a specific value by setting the reset input field to that value. The next time the counter is triggered it will start counting from there. Note that the counter will always output numbers based on the min, max and step values, and setting the reset value does not affect those input fields. If the reset value is not a legal counter value, the counter will still behave as though it is.
If reset is greater than max, the counter is set to max. If reset is less than min, the counter is set to min. If reset is between steps, the counter is set to the lower step value.
Each time a counting cycle is started, the syncOut output is triggered. This output can be used to synchronize some other event with the counting cycle.
SoSFShort min
Minimum value for the counter.
SoSFShort max
Maximum value for the counter.
SoSFShort step
Counter step value.
SoSFTrigger trigger
Go to the next step.
SoSFShort reset
At the next trigger, reset the counter to the specified value.
(SoSFShort) output
Counts min-to-max in step increments.
(SoSFTrigger) syncOut
Triggers at cycle start.
SoCounter()
Constructor
Counter {
min 0 max 1 step 1 trigger reset 0
}
SoTimeCounter, SoEngineOutput