POWERCOM(8) | NUT Manual | POWERCOM(8) |
powercom - UPS driver for serial Powercom/Trust/Advice UPS equipment
This man page only documents the hardware-specific features of the powercom driver. For information about the core driver, see nutupsdrv(8).
This driver supports many similar kinds of serial UPS hardware (as well as a few USB UPS models with USB-to-serial adapters). The most common ones are the Trust 425/625, Powercom, and Advice Partner/King PR750. Others using the same protocol may also work. For USB connections, you might need usbhid-ups(8).
For more specific guidance on which driver is applicable for a USB connection, see the NUT Hardware Compatibility List (HCL).
This driver supports the following optional settings in the ups.conf(5) file:
linevoltage=value
manufacturer=name
modelname=name
serialnumber=value
type=name
BNT-other is a special type for other BNT models (such as the 1500A at 120V and can be used to override ALL models using ALL of the following values.
shutdownArguments={{minutes,seconds},whether_minutes_should_be_used}
numOfBytesFromUPS=value
methodOfFlowControl=name
validationSequence={{index1,value1},{index2,value2},{index3,value3}}
frequency={A,B}
loadPercentage={BatteryA,BatteryB,LineA,LineB}
batteryPercentage={Battery1,Battery2,Battery3,Line4,Line5}
voltage={240A,240B,120A,120B}
linevoltage = 230 manufacturer = PowerCom modelname = Unknown serialnumber = Unknown type = Trust
The rest of the default values for the extra arguments are type-dependent. However, BNT-other is a special type that can be used to override ALL values for ALL models.
numOfBytesFromUPS = 11 methodOfFlowControl = dtr0rts1 validationSequence = {{5,0},{7,0},{8,0}} shutdownArguments = {{0,10},n} frequency = {0.00020997,0.00020928} loadPercentage = {6.1343,-0.3808,4.3110,0.1811} batteryPercentage = {5.0000,0.3268,-825.00,4.5639,-835.82} voltage = {1.9216,-0.0977,0.9545,0.0000}
numOfBytesFromUPS = 16 methodOfFlowControl = dtr0rts1 validationSequence = {{5,0x80},{7,0},{8,0}} shutdownArguments = {{0,10},n} frequency = {0.00020997,0.00020928} loadPercentage = {6.1343,-0.3808,4.3110,0.1811} batteryPercentage = {5.0000,0.3268,-825.00,4.5639,-835.82} voltage = {1.9216,-0.0977,0.9545,0.0000}
numOfBytesFromUPS = 16 methodOfFlowControl = no_flow_control validationSequence = {{5,0x80},{7,0},{8,0}} shutdownArguments = {{0,10},n} frequency = {0.00020997,0.00020928} loadPercentage = {6.1343,-0.3808,1.3333,0.6667} batteryPercentage = {5.0000,0.3268,-825.00,2.2105,-355.37} voltage = {1.9216,-0.0977,0.9545,0.0000}
numOfBytesFromUPS = 16 methodOfFlowControl = no_flow_control validationSequence = {{5,0xFF},{7,0},{8,0}} shutdownArguments = {{1,30},y}
numOfBytesFromUPS = 16 methodOfFlowControl = no_flow_control validationSequence = {{11,0x4b},{8,0},{8,0}} shutdownArguments = {{1,30},y}
numOfBytesFromUPS = 16 methodOfFlowControl = no_flow_control validationSequence = {{11,0x42},{8,0},{8,0}} shutdownArguments = {{1,30},y}
numOfBytesFromUPS = 16 methodOfFlowControl = no_flow_control validationSequence = {{8,0},{8,0},{8,0}} shutdownArguments = {{1,30},y} frequency = {0.00027778,0.0000} loadPercentage = {1.0000,0.0,1.0000,0.0} batteryPercentage = {1.0000,0.0000,0.0000,1.0000,0.0000} voltage = {2.0000,0.0000,2.0000,0.0000}
numOfBytesFromUPS = 16 methodOfFlowControl = no_flow_control validationSequence = {{5,0xFF},{7,0},{8,0}} shutdownArguments = {{1,30},y}
Peter Bieringer <pb@bieringer.de>, Alexey Sidorov <alexsid@altlinux.org>, Keven L. Ates <atescomp@gmail.com>
The NUT (Network UPS Tools) home page: http://www.networkupstools.org/
12/29/2015 | Network UPS Tools 2.7.3. |