NVME-WDC-VS-TELEM(1) | NVMe Manual | NVME-WDC-VS-TELEM(1) |
nvme-wdc-vs-telemetry-controller-option - Disable/Enable the controller initiated option of the telemetry log page.
nvme wdc vs-telemetry-controller-option <device> [--disable, -d] [--enable, -e]
[--status, -s]
For the NVMe device given, sends the WDC Vendor Specific set feature command to disable, enable or get current status of the controller initiated option of the telemetry log page.
The <device> parameter is mandatory NVMe character device (ex: /dev/nvme0).
This will only work on WDC devices supporting this feature. Results for any other device are undefined.
-d, --disable
-e, --enable
-s, --status
# nvme wdc vs-telemetry-controller-option /dev/nvme0 --disable # nvme wdc vs-telemetry-controller-option /dev/nvme0 -d
# nvme wdc vs-telemetry-controller-option /dev/nvme0 --enable # nvme wdc vs-telemetry-controller-option /dev/nvme0 -e
# nvme wdc vs-telemetry-controller-option /dev/nvme0 --status # nvme wdc vs-telemetry-controller-option /dev/nvme0 -s
Part of the nvme-user suite.
04/24/2020 | NVMe |