--allow-code-poke[=True|=False]
- Allow programs to POKE into code memory.
-
--aspect=x,y
- Set the display aspect ratio to x:y. Only has an effect if
combined with --interface=graphical.
- -b
- Use the command-line interface. This is identical to
--interface=cli.
-
--border=width
- Set the width of the screen border as a percentage from 0—100. The
percentage refers to the total width of the borders on both sides as a
fraction of the usable screen width. Only has an effect if combined with
--interface=graphical.
-
--caption=title
- Set the title bar caption of the PC-BASIC window. Default title is
PC-BASIC.
-
--cas1=type:value
- Attach a resource to the CAS1: cassette device.
type:value can be
WAV:wav_file Connect to the RIFF Wave file
wav_file with data modulated in IBM PC cassette format.
CAS:cas_file Connect to the PCE/PC-BASIC CAS
tape image cas_file.
-
--codepage=codepage_id[:nobox]
- Load the specified codepage. The codepage determines which characters are
associated to a given character byte or, in the case of double-byte
codepages, two character bytes. The available codepages are stored in the
codepage/ directory; by default, these are: 437 720
737 775 806 850 851 852
853 855 856 857 858 860
861 862 863 864 865 866
868 869 874 932 934 936
938 949 950 1258 alternativnyj
armscii8a big5-2003 big5-hkscs
georgian-academy georgian-ps iransystem
iscii-as iscii-be iscii-de iscii-gu
iscii-ka iscii-ma iscii-or iscii-pa
iscii-ta iscii-te kamenicky koi8-r
koi8-ru koi8-u mazovia mik osnovnoj
pascii ruscii russup3 russup4ac
russup4na viscii . See the list of codepages in the User's
Guide for details. The specifier nobox disables box-drawing
recognition for double-byte character set code pages. By default,
sequences of box-drawing characters are recognised by an algorithm that
isn't as smart as it thinks it is, and displayed as box drawing rather
than as DBCS characters. If nobox is set, they will be displayed as
DBCS.
-
--config=config_file
- Read a configuration file. The system default configuration is always read
first, but any preset group of options in a configuration file replaces
the whole equivalent default preset group.
-
--com1=type:value
- Attach a resource to the COM1: serial device.
type:value can be one of the following.
PORT:device_name Connect to a serial device.
device_name can be a device name such as COM1 or /dev/ttyS0 or a
number, where the first serial port is number 0.
SOCKET:host:socket Connect to a
TCP socket on a remote or local host.
RFC2217:host:socket Connect using
the RFC2217 protocol to a TCP socket on a remote or local host.
STDIO:[CRLF] Connect to standard I/O of the
calling shell. If CRLF is specified, PC-BASIC replaces CR
characters with LF on its output and LF with CR on its input. This is
more intuitive on Unix shells. When using a Unix console, you should use
stty -icanon to enable PC-BASIC to read input correctly.
If this option is not specified, the COM1: device is
unavailable.
-
--com2=type:value
- Attach a resource to the COM2: serial device. See --com1.
-
--convert={A|B|P}
- Convert program to one of the following formats:
A Plain text
B Tokenised
P Protected
If output is not specified, write to standard output.
If program is not specified, use the argument of --run or
--load. If none of those are given, read from standard input.
Overrides --resume, --run and --load.
-
--mouse-clipboard[=True|=False]
- Enable clipboard operations with the mouse. If True (default),
select text with the left mouse button to copy and paste with the middle
mouse button.
-
--ctrl-c-break[=True|=False]
- If False, follow GW-BASIC behaviour where Ctrl+C breaks AUTO and
INPUT but not program execution or LIST. If True, treat Ctrl+C
exactly like Ctrl+Break and Ctrl+Scroll Lock when
--interface=graphical. With
--interface={text|cli}, Ctrl+C is always treated like
Ctrl+Break. Default is True.
-
--current-device={CAS1|@|A|B ...
|Z}
- Set the current device to the indicated PC-BASIC drive letter or
CAS1 for the cassette device. The device chosen should be mounted
to an actual location using --mount (or --cas1 if the cassette device is
chosen).
-
--debug[=True|=False]
- Developer option - use only if you know what you're doing. Enable
debugging extension.
-
--dimensions=x,y
- Set window dimensions to x by y pixels. This overrides
--scaling=native and --aspect. Only has an effect if combined with
--interface=graphical.
- -d
--double[=True|=False]
- Enable double-precision transcendental math functions. This is equivalent
to the /d option in GW-BASIC.
-
-e=statement[:statement ...]
--exec=statement[:statement ...]
- Execute BASIC statements. The statements are executed after loading
any program but before entering into direct mode or running it. Multiple
statements can be entered by separating them with colons :. These
will be executed as if they were entered as separate statements, not as a
single compound statement; even if statements such as GOTO can be
included, the following statements will be executed. If a : is
intended to be part of a statement, the statement must be quoted with
single quotes '. If your calling shell interprets such quotes, you
should properly escape them.
-
--extension=module_name[,module_name ... ]
- Developer option - use only if you know what you're doing. Load extension
module(s).
-
--font=font_name[,font_name ... ]
- Use the specified fonts for the interface. The last fonts specified take
precedence, previous ones are fallback. Default is
unifont,univga,freedos (i.e. the freedos font has preference). The
available fonts are stored in font/. By default, the following fonts are
available: unifont univga freedos cga
mda vga olivetti tandy1 tandy2 . See
the list of fonts in the User's Guide for details.
-
--fullscreen[=True|=False]
- Fullscreen mode. Only has an effect if combined with
--interface=graphical.
- -h --help
- Show a usage message and exit.
-
--hide-listing=line_number
- Disable listing and saving to plain text of lines beyond
line_number, as in GW-BASIC beyond 65530. Use with care as this
allows execution of hidden lines of code. Default is to list all lines.
-
--hide-protected[=True|=False]
- Disable listing and saving to plain text of protected files, as in
GW-BASIC. Use with care as this allows execution of hidden lines of code.
-
--input={input_file|{STDIO|STDIN}[:RAW]}
- Retrieve keyboard input from input_file, except if KYBD: is read
explicitly. Input from KYBD: files is always read from the keyboard,
following GW-BASIC behaviour. If input_file is STDIO: or
STDIN:, keyboard input will be read from standard input. If
RAW is specified, input will be treated as codepage bytes. If not,
it will be treated as the locale's encoding (probably UTF-8).
-
--interface=[none|cli|text|graphical]
- Choose the type of interface. Not all interfaces will be available on all
systems. The following interface types may be available:
none Filter for use with pipes. Also -n.
cli Command-line interface. Also -b.
text Text interface. Also -t.
graphical Graphical interface.
sdl2 SDL2 graphical interface.
pygame PyGame graphical interface (deprecated, please
use SDL2 instead).
ansi ANSI text interface.
curses NCurses text interface.
The default is graphical.
- -k=keystring
--keys=keystring
- Insert the keystring into the keyboard buffer. keystring may
contain escape codes such as \r for return, \n for line feed and
\xXX to enter CHR$(&HXX). keystring may contain
e-ASCII codes to indicate keypresses that do not have a regular character
encoding. For example, \0\x0F indicates Shift+Tab.
- -l=program
--load=program
- Start in direct mode with the BASIC program loaded.
-
--logfile=log_file
- Write error and warning messages to log_file instead of stderr.
-
--lpt1=type:value
- Attach a resource to the LPT1: parallel device.
type:value can be
PRINTER:[printer_name][:trigger] Connect
to a Windows, LPR or CUPS printer. If printer_name is not
specified, the default printer is used. The printer is activated when a
file open to it is closed, a program terminates or PC-BASIC exits. Note
that, unlike LPT1:, printers connected to LPT2: or LPT3: do not get
activated when a program terminates. If specified, trigger sets
an additional trigger to activate the printer:
line After every line break.
page After every page break.
close No additional trigger
The default behaviour is that of close.
FILE:file_name Connect to any file or device
such as /dev/stdout on Unix or LPT1 on Windows.
STDIO:[CRLF] Connect to standard output of the
calling shell. If CRLF is specified, PC-BASIC replaces CR
characters with LF on its output. This is more intuitive on Unix
shells.
PARPORT:port_number Connect to a Centronics
parallel port, where port_number is 0 for the first
parallel port, etc. PARPORT only works with physical parallel
ports; for example, a Windows printer or other device mapped with NET
USE LPT1: can only be attached with FILE:LPT1
If this option is not specified, LPT1: is connected to the
default printer.
-
--lpt2=type:value
- Attach a resource to the LPT2: parallel device. See --lpt1. If this
option is not specified, LPT2: is unavailable.
-
--lpt3=type:value
- Attach a resource to the LPT3: parallel device. See --lpt1. If this
option is not specified, LPT3: is unavailable.
- -f=number_of_files
--max-files=number_of_files
- Set maximum number of open files to number_of_files. This is
equivalent to the /f option in GW-BASIC. Default is 3.
-
--max-memory=max_memory[,basic_memory_blocks]
- Set the maximum size of the data memory segment to max_memory and
the maximum size of the data memory available to BASIC to
basic_memory_blocks*16. In PC-BASIC, the minimum of these values is
simply the data memory size; the two values are allowed for compatibility
with the /m option in GW-BASIC.
- -s=record_length
--max-reclen=record_length
- Set maximum record length for RANDOM files to record_length.
Default is 128, maximum is 32767. This is equivalent to the
/s option in GW-BASIC.
-
--monitor={rgb|composite|green|amber|grey|mono}
- Sets the monitor type to emulate. Available types are:
rgb RGB colour monitor (default).
composite Composite colour monitor.
green Green-tinted monochrome monitor.
amber Amber-tinted monochrome monitor.
grey Greyscale monochrome monitor.
mono Green-tinted monochrome monitor (same as
green).
On SCREEN 2 with
--video={pcjr|tandy|cga},
--monitor=composite enables (crude) colour artifacts.
-
--mount=drive:path,[drive:path
... ]
- Assign the path path to drive letter drive:. The path can be
absolute or relative. If this option is not specified: on Windows, all
Windows drive letters will be assigned to PC-BASIC drive letters; on other
systems, the current working directory is assigned to Z:.
- -n
- Run PC-BASIC as a command-line filter. Same as --interface=none.
-
--output=output_file[:append]
- Send screen output to output_file, except if SCRN: is written to
explicitly. Output to SCRN: files will always be shown on the screen, as
in GW-BASIC. If the specifier append is given, the output file is
appended to rather than overwritten. If output_file is
STDIO: or STDOUT:, screen output will be sent to standard
output.
-
--peek=[seg:addr:val[,seg:addr:val
... ]]
- Define PEEK preset values. If defined, DEF SEG seg:?
PEEK(addr) will return val.
-
--preset=option_block
- Load machine preset options. A preset option corresponds to a section
defined in a config file by a name between square brackets, like [this]
--preset=this will load all settings defined in that section.
Available presets depend on your configuration file. See the list of
default presets in the User's Guide.
-
--prevent-close[=True|=False]
- Suppress window close event. This allows BASIC to capture key combinations
that normally close the window. Graphical interface only. By default, the
operating system's key combination to close a window (usually Alt+F4)
terminates PC-BASIC. Set --prevent-close to allow BASIC to capture
this key combination instead. This is useful if your program uses this key
combination.
- -q
--quit[=True|=False]
- Quit interpreter when execution stops. If combined with --run, PC-BASIC
quits when the program ends. If set in direct mode, PC-BASIC quits after
the first command is executed.
-
--reserved-memory=number_of_bytes
- Reserve number_of_bytes of memory at the bottom of the data
segment. For compatibility with GW-BASIC. Default is 3429 bytes. Lowering
this value makes more string and variable space available for use by
programs.
-
--resume[=True|=False
- Resume from saved state. Overrides --run and --load.
- -r=program
--run=program
- Run the specified program. Overrides --load.
-
--scaling={smooth|crisp|native}
- Choose scaling method.
smooth The display is smoothly scaled to the largest
size that allows for the correct aspect ratio.
crisp The display is scaled to the same size as with
smooth, but without smoothing.
native Scaling and aspect ratio are optimised for the
display's native pixel size, without smoothing. --scaling=native
overrides --aspect.
Default is smooth. Only has an effect if combined with
--interface=graphical.
-
--serial-buffer-size=size
- Set serial input buffer size. Default is 256. If set to 0, serial
communications are disabled.
-
--shell=[shell-executable]
- Enable the SHELL statement to run the operating system command interpreter
shell-executable. The executable shell-executable should
support MS-DOS's COMMAND.COM calling conventions, in particular its /C
switch. Example command interpreters are CMD.EXE on Windows and "wine
cmd.exe" on Unix. If shell-executable is empty (as it is by
default), the SHELL statement is disabled.
-
--soft-linefeed[=True|=False]
- Do not treat LF in text and program files as a line break. This enables
the highest level of compatibility with GW-BASIC files. If this option is
set, any Linux or Mac text files need to be converted to DOS text before
using them with PC-BASIC.
-
--sound=[none|beep|portaudio|interface]
- Choose the sound engine to use. Not all sound engines will be available on
all systems.
none Suppress sound output.
beep Use the built-in speaker.
portaudio Use the PortAudio sound generator.
interface Use the native sound engine of the interface,
if available.
Default is interface.
-
--state=state_file
- Set the save-state file to state_file. Default is pcbasic.session
in the Application Data directory.
-
--syntax={advanced|pcjr|tandy}
- Choose BASIC dialect. Available dialects are:
advanced Microsoft GW-BASIC and IBM BASICA
pcjr IBM PCjr Cartridge BASIC
tandy Tandy 1000 GW-BASIC.
Default is advanced.
- -t
- Use text-based interface. Same as --interface=text.
-
--term=terminal_program
- Set the terminal program run by the PCjr TERM command to
terminal_program. This only has an effect with
--syntax={pcjr|tandy}.
-
--text-width={40|80}
- Set the number of columns in text mode at startup. Default is 80.
-
--text-encoding=[encoding]
- Set the text encoding. Text files (i.e. plain-text programs and files
opened for INPUT and OUTPUT) stored on a disk device will be assumed to be
encoded in encoding. Examples of valid encodings are utf-8, utf-16,
latin-1. Please ensure that all characters in the current codepage are
included in the encoding you choose; if this is not the case then such
characters will be replaced by � or ?. If encoding is not
set, text files will be treated as raw bytes in the current PC-BASIC
codepage.
-
--utf8[=True|=False]
- Set the text encoding to UTF-8. This option is deprecated and ignored if
--text-encoding is set. Use --text-encoding instead.
- -v --version
- Print PC-BASIC version string and exit.
-
--video=adapter
- Set the video adapter to emulate. Available adapters:
vga Video Graphics Array
ega Enhanced Graphics Adapter
cga Color/Graphics Adapter
mda Monochrome Display Adapter
hercules Hercules Graphics Adapter
pcjr IBM PCjr graphics
tandy Tandy 1000 graphics
olivetti Olivetti M24 graphics
Default is vga.
-
--video-memory=size
- Set the amount of emulated video memory available. This affects the number
of video pages that can be used. On PCjr and Tandy, this can be changed at
runtime through the CLEAR statement; at least 32768 needs to be available
to enter SCREEN 5 and SCREEN 6. Default is 16384 or PCjr and Tandy
and 262144 on other machine presets.
- -w
--wait[=True|=False]
- If True, PC-BASIC waits for a keystroke before closing the window
on exit. Only works for --interface=graphical or
--interface=text. Default is False.
-
--options=gwbasic_options
- Set GW-BASIC-style command-line switches. This is a convenience option to
facilitate migration from GW-BASIC. gwbasic_options is a string
that may contain the following options:
/d Enable double-precision floating-point math
functions. See also --double.
/f:n Set the maximum number of open files. See
also --max-files.
/s:n Set the maximum record length for RANDOM
files. See also --max-reclen.
/c:n Set the size of the receive buffer for COM
devices. See also --serial-buffer-size.
/i Statically allocate file control blocks and data
buffer. Note that this is already the default approach in GW-BASIC and
PC-BASIC so that this option has no effect.
/m:n,m Set the highest memory location
to n and maximum BASIC memory size to m*16 bytes. See also
--max-memory.
>filename Write screen output to
filename. See also --output.
>>filename Append screen output to
filename. See also --output.
<filename Read keyboard input from
filename. See also --input.
GW-BASIC-style switches are not case sensitive. Note that the
symbols used in these switches may have different meaning in the shell
from which PC-BASIC is called; you should quote and escape the options