waybar-temperature(5) | File Formats Manual | waybar-temperature(5) |
waybar - temperature module
The temperature module displays the current temperature from a thermal zone.
Addressed by temperature
thermal-zone:
typeof: integer
The thermal zone, as in /sys/class/thermal/.
hwmon-path:
typeof: string
The temperature path to use, e.g. /sys/class/hwmon/hwmon2/temp1_input
instead of one in /sys/class/thermal/.
hwmon-path-abs:
typeof: string
The path of the hwmon-directory of the device, e.g.
/sys/devices/pci0000:00/0000:00:18.3/hwmon. (Note that the
subdirectory hwmon/hwmon#, where # is a number is not part of
the path!) Has to be used together with input-filename.
input-filename:
typeof: string
The temperature filename of your hwmon-path-abs, e.g.
temp1_input
critical-threshold:
typeof: integer
The threshold before it is considered critical (Celsius).
interval:
typeof: integer
default: 10
The interval in which the information gets polled.
format-critical:
typeof: string
The format to use when temperature is considered critical
format:
typeof: string
default: {temperatureC}°C
The format (Celsius/Fahrenheit/Kelvin) in which the temperature should be
displayed.
format-icons:
typeof: array
Based on the current temperature (Celsius) and critical-threshold if
available, the corresponding icon gets selected. The order is low to
high.
rotate:
typeof: integer
Positive value to rotate the text label.
max-length:
typeof: integer
The maximum length in characters the module should display.
on-click:
typeof: string
Command to execute when you clicked on the module.
on-click-middle:
typeof: string
Command to execute when middle-clicked on the module using mousewheel.
on-click-right:
typeof: string
Command to execute when you right clicked on the module.
on-update:
typeof: string
Command to execute when the module is updated.
on-scroll-up:
typeof: string
Command to execute when scrolling up on the module.
on-scroll-down:
typeof: string
Command to execute when scrolling down on the module.
smooth-scrolling-threshold:
typeof: double
Threshold to be used when scrolling.
tooltip:
typeof: bool
default: true
Option to disable tooltip on hover.
{temperatureC}: Temperature in Celsius.
{temperatureF}: Temperature in Fahrenheit.
{temperatureK}: Temperature in Kelvin.
"temperature": { // "thermal-zone": 2, // "hwmon-path": "/sys/class/hwmon/hwmon2/temp1_input", // "critical-threshold": 80, // "format-critical": "{temperatureC}°C ", "format": "{temperatureC}°C " }