ao-cal-freq - Calibrate AltOS flight computer frequency
ao-cal-freq [-T tty-device] [--tty
tty-device] [-D altos-device] [--device altos-device]
[-v] [--verbose] [-n] [--nosave] [-o cal-value-output-file] [--output
cal-value-output-file]
ao-cal-freq drives the frequency calibration process and
saves the result.
- -T tty-device | --tty
tty-device
- This selects which tty device the debugger uses to communicate with the
target device. The special name 'BITBANG' directs ao-dbg to use the cp2103
connection, otherwise this should be a usb serial port connected to a
suitable cc1111 debug node.
- -D AltOS-device | --device
AltOS-device
- Search for a connected device. This requires an argument of one of the
following forms:
- TeleMega:2
TeleMega
2
- Leaving out the product name will cause the tool to select a suitable
product, leaving out the serial number will cause the tool to match one of
the available devices.
- -o cal-value-output-file | --output
cal-value-output-file
- Writes the resulting calibration value to the specified file.
- -n | --nosave
- Inhibits saving the calibration value on the device. Necessary for devices
which don't have on-board configuration storage.
- -v | --verbose
- Makes ao-cal-freq chatty about communication with the target
device.
ao-cal-freq opens the target device, interactively
calibrates the frequency, then shows the resulting calibration values and
(optionally) saves them to configuration memory and/or a file.