ipmiutil_reset - perform a hardware reset on the system
ipmiutil reset [-bcdDefhijmnoprsuwxy -N node -U user -P/-R pswd
-EFJTVY]
ipmiutil reset is a program that uses IPMI commands to
perform a hardware reset of the chassis, or boot to a specific device. This
utility can use either the /dev/ipmi0 driver from OpenIPMI, the /dev/imb
driver from Intel, the /dev/ipmikcs driver from valinux, direct user-space
IOs, or the IPMI LAN interface if -N.
Command line options are described below.
- -c
- Power Cycle the system chassis
- -d
- Power Down the system chassis
- -n
- Send NMI to the system
- -u
- Power Up the system chassis
- -r
- Hard Reset the system chassis
- -D
- Do a soft shutdown of the OS, and then power down. Note that remote soft
shutdown (-D -N) for Intel S5000 baseboard requires ipmiutil getevt -a
running on the target server.
- -o
- Do a soft shutdown of the OS, and then reset. Note that remote soft
shutdown (-o -N) for Intel S5000 baseboard requires ipmiutil getevt -a
running on the target server.
- -k
- Do a cold reset to restart the BMC firmware.
- -m 002000s
- Perform these function for a specific MC (e.g. bus 00, sa 20, lun 00). The
trailing character, if present, indicates SMI addressing if 's', or IPMB
addressing if 'i' or not present.
- -b
- Do a hard reset and reboot to the BIOS Setup menu, for this reboot
only.
- -e
- Do a hard reset to EFI, if IPMI EFI boot is enabled, for this reboot
only.
- -f
- Do a hard reset to Floppy/Removable, for this reboot only.
- -h
- Do a hard reset to a Hard Disk, for this reboot only.
- -i
- Set the boot Initiator mailbox string, usually for PXE use. The string
must be less than 78 characters.
- -j
- Set the IANA number used for the boot Initiator mailbox string.
- -p
- Do a hard reset and network boot to PXE server, for this reboot only.
- -s
- Do a hard reset and reboot to the Service/Diagnostic Partition, for this
reboot only. Reboots to the default if no service partition is
configured.
- -v
- Do a hard reset to DVD/CDROM Media, for this reboot only.
- -w
- Wait for BMC ready after a reset before exiting the utility.
- -x
- Causes extra debug messages to be displayed.
- -y
- Yes, try to persist any boot options used [-befhprsv]. This requires the
IPMI firmware to ask the BIOS to change boot order settings, so it may not
be supported by all BMC firmware vendors.
- -N nodename
- Nodename or IP address of the remote target system. If a nodename is
specified, IPMI LAN interface is used. Otherwise the local system
management interface is used.
- -P/-R rmt_pswd
- Remote password for the nodename given. The default is a null
password.
- -U rmt_user
- Remote username for the nodename given. The default is a null
username.
- -E
- Use the remote password from Environment variable IPMI_PASSWORD.
- -F drv_t
- Force the driver type to one of the followng: imb, va, open, gnu, landesk,
lan, lan2, lan2i, kcs, smb. Note that lan2i means lan2 with intelplus. The
default is to detect any available driver type and use it.
- -J
- Use the specified LanPlus cipher suite (0 thru 17): 0=none/none/none,
1=sha1/none/none, 2=sha1/sha1/none, 3=sha1/sha1/cbc128,
4=sha1/sha1/xrc4_128, 5=sha1/sha1/xrc4_40, 6=md5/none/none, ...
14=md5/md5/xrc4_40. Default is 3.
- -T
- Use a specified IPMI LAN Authentication Type: 0=None, 1=MD2, 2=MD5,
4=Straight Password, 5=OEM.
- -V
- Use a specified IPMI LAN privilege level. 1=Callback level, 2=User level,
3=Operator level, 4=Administrator level (default), 5=OEM level.
- -Y
- Yes, do prompt the user for the IPMI LAN remote password. Alternatives for
the password are -E or -P.
See http://ipmiutil.sourceforge.net/ for the latest version of