SMP_ZONE_ACTIVATE(8) | SMP_UTILS | SMP_ZONE_ACTIVATE(8) |
smp_zone_activate - invoke ZONE ACTIVATE SMP function
smp_zone_activate [--expected=EX] [--help] [--hex] [--interface=PARAMS] [--raw] [--sa=SAS_ADDR] [--verbose] [--version] SMP_DEVICE[,N]
Sends a SAS Serial Management Protocol (SMP) ZONE ACTIVATE function request to an SMP target. The SMP target is identified by the SMP_DEVICE and the --sa=SAS_ADDR. Depending on the interface, the SAS_ADDR may be deduced from the SMP_DEVICE. The mpt interface uses SMP_DEVICE to identify a HBA (an SMP initiator) and needs the additional ,N to differentiate between HBAs if there are multiple present.
This function, if successful, will cause various zoning related shadow values (e.g. zone permission table and zone phy information) to be copied to the corresponding current values. If the saving to "saved" values option has been selected then the various zoning related shadow values will also be copied to the corresponding saved values.
Mandatory arguments to long options are mandatory for short options as well.
The SMP ZONE ACTIVATE function was introduced in SAS-2 .
Written by Douglas Gilbert.
Report bugs to <dgilbert at interlog dot com>.
Copyright © 2011 Douglas Gilbert
This software is distributed under a FreeBSD license. There is NO warranty;
not even for MERCHANTABILITY or FITNESS FOR A PARTICULAR PURPOSE.
smp_utils, smp_zone_lock, smp_zone_unlock, smp_ena_dis_zoning(smp_utils)
June 2011 | smp_utils-0.96 |