wavemonrc is the per-user configuration file for
wavemon(1). This page describes its individual configuration options.
Each corresponds to a configuration item of the Preferences screen
(F7 key), whose on-screen name is shown in parentheses.
interface = <ifname>
(Interface)
Selects the wireless interface to use.
cisco_mac = (on|off)
(Cisco-style MAC addresses)
If enabled, display MAC addresses using lower-case hex
digits separated by dots rather than colons.
sort_order =
(channel|essid|mac|signal|open|chan/sig|open/sig)
(Scan sort type)
Determines the ordering used in the scan window:
channel sorts by channel number, essid by access point name,
mac by MAC address, signal by signal strength, and open
by openness. The combined variants chan/sig and open/sig sort
first by channel/openness and then by signal strength. It also affects the
status line at the bottom: normally the most crowded channels are listed,
sorting by channel in descending order switches to least crowded ones
instead.
sort_ascending = (on|off)
(Scan sort direction)
Sets the direction of the sort_order: ascending
(on) or descending (off).
stat_updates = <n>
(Statistics updates)
Time interval for polling new statistics (including scan
refresh). Range: 10..4000ms.
lhist_slot_size = <n>
(Histogram update cycles)
Number of samples used per each histogram slot. For
example, if the stat_updates interval is 500ms and the histogram slot size is
4, the histogram is moved one slot further every 2 seconds. Range:
1..64.
meter_smoothness = <n>
(Level meter smoothness)
Determines the responsiveness of level meters, tracking
the moving average rather than following each new sample. The given value
specifies the percentage of the history (the 'inertia') of preceding samples.
A value of 0 disables this option. Range: 0..99%.
info_updates = <n>
(Dynamic info updates)
Sets refresh rate for dynamic device parameters (e.g.
bitrate) and the refresh interval for the Scan window (F3). Range:
1..60s.
override_auto_scale = (on|off)
(Override scale autodetect)
Override the auto-scaling of the bar graphs and
histogram, allowing you to set your own scales.
min_signal_level, max_signal_level = <n>
(Minimum signal level, Maximum signal level)
Set the left and right boundaries of the signal level
scales. Ranges: -100..-39 (minimum) and -40..-10dBm (maximum).
min_noise_level, max_noise_level = <n>
(Minimum noise level, Maximum noise level)
These work similar to the signal boundary settings.
Ranges: -120..-70dBm (minimum) and -69..-40dBm (maximum).
lo_threshold_action = (disabled|beep|flash|beep+flash)
(Low threshold action)
Issue a warning at a given threshold at the lower end of
the signal scale. It is meant for alarming you when a signal appears at the
receiver.
lo_threshold = <n>
(Low threshold)
Sets the threshold value for the 'Low threshold action'.
Range: -120..-60dBm.
hi_threshold_action = (disabled|beep|flash|beep+flash)
(High threshold action)
Analogous to lo_threshold_action, only this time the
threshold is at the upper end of the scale and the action is performed when
the signal level drops below it. The acoustic signal is also different in
order to be easily distinguishable from the lower one. Correctly adjusted,
this little fellow will tell you when you should move closer to the base
station.
hi_threshold = <n>
(High threshold)
Sets the threshold for the 'High threshold action'.
Range: -59..120dBm.
transparent_bg = (on|off)
(Use transparent background)
If enabled, use a transparent background instead of
black. This is enabled by default and can only be turned off via the startup
file.
startup_screen = (info|histogram|scan window)
(Startup screen)
Which of the screens appears at program startup.