DOKK / manpages / debian 12 / waybar / waybar-temperature.5.en
waybar-temperature(5) File Formats Manual waybar-temperature(5)

waybar - temperature module

The temperature module displays the current temperature from a thermal zone.

Addressed by temperature

thermal-zone:
typeof: integer
The thermal zone, as in /sys/class/thermal/.

hwmon-path:
typeof: string
The temperature path to use, e.g. /sys/class/hwmon/hwmon2/temp1_input instead of one in /sys/class/thermal/.

hwmon-path-abs:
typeof: string
The path of the hwmon-directory of the device, e.g. /sys/devices/pci0000:00/0000:00:18.3/hwmon. (Note that the subdirectory hwmon/hwmon#, where # is a number is not part of the path!) Has to be used together with input-filename.

input-filename:
typeof: string
The temperature filename of your hwmon-path-abs, e.g. temp1_input

critical-threshold:
typeof: integer
The threshold before it is considered critical (Celsius).

interval:
typeof: integer
default: 10
The interval in which the information gets polled.

format-critical:
typeof: string
The format to use when temperature is considered critical

format:
typeof: string
default: {temperatureC}°C
The format (Celsius/Fahrenheit/Kelvin) in which the temperature should be displayed.

format-icons:
typeof: array
Based on the current temperature (Celsius) and critical-threshold if available, the corresponding icon gets selected. The order is low to high.

tooltip-format:
typeof: string
default: {temperatureC}°C
The format for the tooltip

rotate:
typeof: integer
Positive value to rotate the text label.

max-length:
typeof: integer
The maximum length in characters the module should display.

min-length:
typeof: integer
The minimum length in characters the module should take up.

align:
typeof: float
The alignment of the text, where 0 is left-aligned and 1 is right-aligned. If the module is rotated, it will follow the flow of the text.

on-click:
typeof: string
Command to execute when you clicked on the module.

on-click-middle:
typeof: string
Command to execute when middle-clicked on the module using mousewheel.

on-click-right:
typeof: string
Command to execute when you right clicked on the module.

on-update:
typeof: string
Command to execute when the module is updated.

on-scroll-up:
typeof: string
Command to execute when scrolling up on the module.

on-scroll-down:
typeof: string
Command to execute when scrolling down on the module.

smooth-scrolling-threshold:
typeof: double
Threshold to be used when scrolling.

tooltip:
typeof: bool
default: true
Option to disable tooltip on hover.

{temperatureC}: Temperature in Celsius.

{temperatureF}: Temperature in Fahrenheit.

{temperatureK}: Temperature in Kelvin.


"temperature": { // "thermal-zone": 2, // "hwmon-path": "/sys/class/hwmon/hwmon2/temp1_input", // "critical-threshold": 80, // "format-critical": "{temperatureC}°C ", "format": "{temperatureC}°C " }

#temperature
#temperature.critical
2023-02-28